Search found 23 matches

by aparna.p
March 28th, 2012, 10:18 pm
Forum: Civil Construction
Topic: how to complain to BBMP on neighbour violating rules
Replies: 11
Views: 29234

Re: how to complain to BBMP on neighbour violating rules

Hi,

PFA building byelaws.

Regards
aparna
*****************
****************

You can advertise only once you attain the contributor status,keep sharing the knowledge

Edited by Admin
by aparna.p
March 20th, 2012, 11:20 am
Forum: Civil Construction
Topic: Suggestion on construction on 40x30
Replies: 3
Views: 4554

Re: Suggestion on construction on 40x30

Hi Venky,

elevation will always comes good when the width (road side) of the site is more than depth since surface area is more and we can work better options.


EDITED BY ADMIN
by aparna.p
March 3rd, 2012, 8:16 pm
Forum: Civil Construction
Topic: Kitchen Dimension
Replies: 9
Views: 9971

Re: Kitchen Dimension

Hi,

The kitchen size is wheather large / medium/small is determined based on the length of the counter.If the counter length is 8-10ft -small(for 2 person),10-12-medium,above 13 large.In your case if the sapce behind puja room is used for fridge/sink then counter length will be 6'6''+3'6''=10 ...
by aparna.p
February 26th, 2012, 9:06 am
Forum: Civil Construction
Topic: external staircase
Replies: 2
Views: 3954

Re: external staircase

Concrete staircase room are not allowed in setback area.only temp staircase without roof and side walls are ok.
by aparna.p
February 26th, 2012, 8:59 am
Forum: Civil Construction
Topic: Cut Lintel Vs Full Lintel
Replies: 9
Views: 15890

Re: Cut Lintel Vs Full Lintel

Hi,

Running a through lintel is expensive and not required. Lintels are required ony where there is opening like window , door , niches.
chejjas are required for external doors and windows, wherever required they will extend the 100mm thick lintel to 450mm wide(outside).It will be strong enough.
by aparna.p
February 13th, 2012, 1:26 pm
Forum: Civil Construction
Topic: 2 storey construction on a 1200 st site
Replies: 8
Views: 10821

Re: 2 storey construction on a 1200 st site

BBMP BYELAWS.pdf

Please refer the attachement for new BBMP rules. In page no-22 it is clearly written that basement is not allowed if the site area is less than 200sqmt.
In 1200sqft site , you can build stilt(above road level)+ ground + 2 floors ( ht of the building is ristricted to 11.5mt/37ft ...
by aparna.p
January 19th, 2012, 5:38 pm
Forum: Civil Construction
Topic: ceramic tiles for flooring
Replies: 5
Views: 6161

Re: ceramic tiles for flooring

Hi Sudhu Kumar,

Ceramic tiles are substitute for vitrified tiles , but not for other flooring .Both vitrified and ceramic tiles are used for Apartment, commercial building and for those houses which will be rented and not for own house since they chip very fast while moving heavy items like fridge ...
by aparna.p
November 28th, 2011, 6:04 pm
Forum: Civil Construction
Topic: Partial abbotting the wall on one side ?
Replies: 8
Views: 7774

Re: Partial abbotting the wall on one side ?

same as rectangle site , left and back side site measement to be considered for 1/3 rd length.
by aparna.p
November 22nd, 2011, 10:46 am
Forum: Civil Construction
Topic: Partial abbotting the wall on one side ?
Replies: 8
Views: 7774

Re: Partial abbotting the wall on one side ?

yes when you are facing the site.
by aparna.p
November 21st, 2011, 5:31 pm
Forum: Civil Construction
Topic: Partial abbotting the wall on one side ?
Replies: 8
Views: 7774

Re: Partial abbotting the wall on one side ?

According to BDA rules, abbotting is allowed on left end corner by 1/3 of the width and length.For example if your site is 30x40 , you can build till the site end on your left end corner by10ft on width side and 13.3ft on length of site side.

Go to advanced search